Specifications
| VL-S-232A | |
|---|---|
| Function | Safety limiter (hi-limit), manual reset — trips open on over-temperature and stays open until manually reset |
| Trip point (VL-S-232A) | 232 ± 8°C (450°F), fixed; other trip points to order |
| Rating — VL-S-232A drawing | DC 0–50V · 0–1A (millivolt / low-voltage safety circuits) |
| Rating — series nameplate | AC 400V 30A · DC 50V 1A · 30,000 cycles (CE test report ratings for the VL-S series) |
| Contact form | SPDT |
| Capillary | Nickel-plated copper, Ø2.0mm × 800mm; length made to order (e.g. 30″ to match the original hi-limit) |
| Bulb | Ø6.5 × 114mm |
| Gland (stuffing box) | 3/8″-18 NPT |
| Body | 54 × 47mm; maximum body temperature T105°C |
| Certification | UL Recognized Component, file E491946 (UL 60730-1 / UL 60730-2-9) · CE certified (EN 60730-1 / EN IEC 60730-2-9) |
Technical data is a catalogue reference. Confirm final ratings, dimensions and approvals for the selected model before ordering.
Two ratings appear above because they describe two different things. The drawing rating (DC 0–50V / 1A) is the rating of the standard VL-S-232A fryer variant, which switches the millivolt safety circuit. The series nameplate rating (AC 400V 30A) covers the line-voltage versions of the same VL-S series, as tested for the CE report. Tell us which circuit the limiter protects and we confirm the correct variant in writing.
The family
Manual-reset safety limiter. Trips on over-temperature and latches open until a technician resets it — the standard hi-limit behaviour for commercial fryers.
Fixed trip · standard 232°C (450°F) · UL + CE
Automatic-reset safety limiter. Trips on over-temperature and re-closes as the equipment cools.
Fixed trip · standard 232°C (450°F) · UL
The operating control half of the pair: adjustable millivolt thermostat, 200–400°F, for the same gas fryers and ovens.
Millivolt · 200–400°F · UL + CE
All three series are covered by UL file E491946. The VL-S series is also CE certified.
Replacement cross-reference
The VL-S-232A is built as the replacement equivalent of the Robertshaw 5225-series manual-reset hi-limit below; its automatic-reset counterpart is the VL-Z. Capillary length is made to the inch specification of the original part.
| Original part | HengTherm equivalent | Specification |
|---|---|---|
| Robertshaw LCHM050300000 | VL-S-232A | Manual reset · fixed 450°F (232°C) trip · 30″ capillary · 3/8″-18 NPT gland |
| Robertshaw LCCM200300000 | VL-Z-232A | Automatic reset · fixed 450°F (232°C) trip · 30″ capillary |
Replacing the matching 5300-series control as well? The full part-by-part mapping — RX-1-36, RX-2-24 and RX-10-24 included — is in our Robertshaw cross-reference guide.
HengTherm parts are replacement equivalents manufactured by Guangzhou V.Crown Thermostat Co., Ltd. They are not manufactured by, or affiliated with, Robertshaw. Part numbers are used for cross-reference identification only.
UL & CE certification
The VL-S and VL-Z series are UL Recognized Components under file E491946 (US certificate UL-US-2412050-1, Canada UL-CA-2410266-1; UL 60730-1 / UL 60730-2-9), issued 20 November 2024 to Guangzhou V.Crown Thermostat Co., Ltd. Verify on UL Product iQ (search E491946). The VL-S series is also CE certified: tested to EN 60730-1 / EN IEC 60730-2-9 (Shenzhen An-Xin test report AXJC20240912000111S, 25 September 2024, covering the VL-S-232A and the VL-S series; nameplate ratings AC 400V 30A / DC 50V 1A, 30,000 cycles).
Certifications · UL certificate (PDF)
Downloads
- VL-S-232A — technical drawing, manual-reset safety limiter, 232°C trip (PDF)
- VL-S-232B — technical drawing, manual-reset safety limiter (PDF)
- VL-Z-232A — technical drawing, automatic-reset safety limiter (PDF)
Customization & samples
Trip point, capillary length and gland are made to order; development for mechanical customization is free of charge. Free samples of the VL-S are available for bench testing — you only cover the courier, and the freight is credited against your first order. Trial orders start from 200 pcs, with models mixed in one shipment.
Applications
- Gas deep fryers (hi-limit protection)
- Gas ovens and ranges
- Electric fryers and boilers (AC-rated variants)
- Commercial cooking equipment safety circuits
FAQ
Is the VL-S-232A a direct replacement for the Robertshaw LCHM050300000?
It matches on the points that matter for a hi-limit: manual reset, a fixed 450°F (232°C) trip, SPDT contact and a 3/8″-18 NPT gland, with the capillary made to the original 30″ specification. Check the VL-S-232A drawing (downloads above) against your part before ordering.
What is the difference between the VL-S and the VL-Z?
Reset behaviour. The VL-S is manual-reset: once it trips it stays open until a technician resets it. The VL-Z is automatic-reset: it re-closes as the equipment cools. Both have a standard 232°C (450°F) trip and are covered by UL file E491946; the VL-S series is also CE certified. Never swap one reset type for the other to make a cross-reference fit.
Which rating applies — DC 0–50V / 1A or AC 400V / 30A?
Both are real, for different variants. The standard VL-S-232A fryer variant is rated DC 0–50V / 1A for millivolt and low-voltage safety circuits; the VL-S series nameplate also covers AC 400V 30A versions for line-voltage equipment (CE test report ratings). Tell us your circuit and we confirm the variant before quoting.
Replacing a UL-listed Cotherm limiter? Our Cotherm cross-reference guide maps the GTLUR / GTLUR3 manual-reset types to the VL-S and the GTLU / GTLU3 automatic-reset types to the VL-Z.
all products · Capillary Control Thermostats · Manual Reset Safety Limit Thermostats · High-Current Control Thermostats · Gas Thermostats & Limiters · ARB-33 Millivolt Thermostat · AG16-K Capillary Thermostat · AG32-1K High-Current Thermostat · Capillary Thermometers · Custom Thermostat Knobs