VL-S Safety Limit Thermostat

The VL-S is a capillary safety limiter (hi-limit): wired in series with the operating control, it does nothing until the equipment overheats — then it trips open and stays open until it is reset by hand. The standard VL-S-232A trips at 232°C (450°F), the classic gas-fryer hi-limit point, with a DC 0–50V / 1A rating for millivolt and low-voltage safety circuits. The series is a UL Recognized Component (file E491946, US & Canada) and CE certified.

VL-S-232A safety limiter — technical drawing
VL-S-232A technical drawing — manual-reset limiter, 232°C trip (drawing shown; no catalogue photo)

Specifications

VL-S-232A
FunctionSafety limiter (hi-limit), manual reset — trips open on over-temperature and stays open until manually reset
Trip point (VL-S-232A)232 ± 8°C (450°F), fixed; other trip points to order
Rating — VL-S-232A drawingDC 0–50V · 0–1A (millivolt / low-voltage safety circuits)
Rating — series nameplateAC 400V 30A · DC 50V 1A · 30,000 cycles (CE test report ratings for the VL-S series)
Contact formSPDT
CapillaryNickel-plated copper, Ø2.0mm × 800mm; length made to order (e.g. 30″ to match the original hi-limit)
BulbØ6.5 × 114mm
Gland (stuffing box)3/8″-18 NPT
Body54 × 47mm; maximum body temperature T105°C
CertificationUL Recognized Component, file E491946 (UL 60730-1 / UL 60730-2-9) · CE certified (EN 60730-1 / EN IEC 60730-2-9)

Technical data is a catalogue reference. Confirm final ratings, dimensions and approvals for the selected model before ordering.

Two ratings appear above because they describe two different things. The drawing rating (DC 0–50V / 1A) is the rating of the standard VL-S-232A fryer variant, which switches the millivolt safety circuit. The series nameplate rating (AC 400V 30A) covers the line-voltage versions of the same VL-S series, as tested for the CE report. Tell us which circuit the limiter protects and we confirm the correct variant in writing.

The family

VL-S

Manual-reset safety limiter. Trips on over-temperature and latches open until a technician resets it — the standard hi-limit behaviour for commercial fryers.

Fixed trip · standard 232°C (450°F) · UL + CE

VL-Z

Automatic-reset safety limiter. Trips on over-temperature and re-closes as the equipment cools.

Fixed trip · standard 232°C (450°F) · UL

ARB-33

The operating control half of the pair: adjustable millivolt thermostat, 200–400°F, for the same gas fryers and ovens.

Millivolt · 200–400°F · UL + CE

ARB-33 millivolt thermostat →

All three series are covered by UL file E491946. The VL-S series is also CE certified.

Replacement cross-reference

The VL-S-232A is built as the replacement equivalent of the Robertshaw 5225-series manual-reset hi-limit below; its automatic-reset counterpart is the VL-Z. Capillary length is made to the inch specification of the original part.

Original partHengTherm equivalentSpecification
Robertshaw LCHM050300000VL-S-232AManual reset · fixed 450°F (232°C) trip · 30″ capillary · 3/8″-18 NPT gland
Robertshaw LCCM200300000VL-Z-232AAutomatic reset · fixed 450°F (232°C) trip · 30″ capillary

Replacing the matching 5300-series control as well? The full part-by-part mapping — RX-1-36, RX-2-24 and RX-10-24 included — is in our Robertshaw cross-reference guide.

HengTherm parts are replacement equivalents manufactured by Guangzhou V.Crown Thermostat Co., Ltd. They are not manufactured by, or affiliated with, Robertshaw. Part numbers are used for cross-reference identification only.

UL & CE certification

The VL-S and VL-Z series are UL Recognized Components under file E491946 (US certificate UL-US-2412050-1, Canada UL-CA-2410266-1; UL 60730-1 / UL 60730-2-9), issued 20 November 2024 to Guangzhou V.Crown Thermostat Co., Ltd. Verify on UL Product iQ (search E491946). The VL-S series is also CE certified: tested to EN 60730-1 / EN IEC 60730-2-9 (Shenzhen An-Xin test report AXJC20240912000111S, 25 September 2024, covering the VL-S-232A and the VL-S series; nameplate ratings AC 400V 30A / DC 50V 1A, 30,000 cycles).

Certifications · UL certificate (PDF)

Downloads

Customization & samples

Trip point, capillary length and gland are made to order; development for mechanical customization is free of charge. Free samples of the VL-S are available for bench testing — you only cover the courier, and the freight is credited against your first order. Trial orders start from 200 pcs, with models mixed in one shipment.

Applications

FAQ

Is the VL-S-232A a direct replacement for the Robertshaw LCHM050300000?

It matches on the points that matter for a hi-limit: manual reset, a fixed 450°F (232°C) trip, SPDT contact and a 3/8″-18 NPT gland, with the capillary made to the original 30″ specification. Check the VL-S-232A drawing (downloads above) against your part before ordering.

What is the difference between the VL-S and the VL-Z?

Reset behaviour. The VL-S is manual-reset: once it trips it stays open until a technician resets it. The VL-Z is automatic-reset: it re-closes as the equipment cools. Both have a standard 232°C (450°F) trip and are covered by UL file E491946; the VL-S series is also CE certified. Never swap one reset type for the other to make a cross-reference fit.

Which rating applies — DC 0–50V / 1A or AC 400V / 30A?

Both are real, for different variants. The standard VL-S-232A fryer variant is rated DC 0–50V / 1A for millivolt and low-voltage safety circuits; the VL-S series nameplate also covers AC 400V 30A versions for line-voltage equipment (CE test report ratings). Tell us your circuit and we confirm the variant before quoting.

Replacing a UL-listed Cotherm limiter? Our Cotherm cross-reference guide maps the GTLUR / GTLUR3 manual-reset types to the VL-S and the GTLU / GTLU3 automatic-reset types to the VL-Z.

all products · Capillary Control Thermostats · Manual Reset Safety Limit Thermostats · High-Current Control Thermostats · Gas Thermostats & Limiters · ARB-33 Millivolt Thermostat · AG16-K Capillary Thermostat · AG32-1K High-Current Thermostat · Capillary Thermometers · Custom Thermostat Knobs